Phoenix Modular switch head station 10/100Mbps Manual de usuario Pagina 169

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 266
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 168
Configuration and Diagnostics
6874_en_09 PHOENIX CONTACT 4-97
flWorkFWConfigStatus
flWorkFWConfigExecute
flWorkFWRunningConfig
OID 1.3.6.1.4.1.4346.11.11.11.2.5.10.4
Syntax Integer
Access Read
Description This object provides information about the last TFTP transmission called:
Transmission OK 1
Transmission not OK 2
No transmission 3
Unknown 4
OID 1.3.6.1.4.1.4346.11.11.11.2.5.10.5
Syntax Integer
Access Read and write
Description This object can be used to load or save configuration data:
No transmission 1
Transmission from server to switch 2
Transmission from switch to server 3
If the new configuration is not activated by a reset after a configuration
download, when the configuration is saved the previously loaded
configuration is rejected and instead the active configuration of the MMS is
saved.
OID 1.3.6.1.4.1.4346.11.11.11.2.5.10.6
Syntax Integer
Access Read
Description This object can be used to request the status of the configuration data transmission:
Not started 1
Transmission in progress 2
Transmission successful 3
Connection error 4
Incorrect file/path name 5
Error 6
Vista de pagina 168
1 2 ... 164 165 166 167 168 169 170 171 172 173 174 ... 265 266

Comentarios a estos manuales

Sin comentarios