Configuration and Diagnostics
6874_en_09 PHOENIX CONTACT 4-101
flWorkFWCtrlAlarmContactEventLinkState
flWorkFWCtrlAlarmContactEventSecurityPortBlocked
flWorkFWCtrlAlarmContactEventPoEFaultDetected
flWorkFWCtrlAlarmContactEnable
OID 1.3.6.1.4.1.4346.11.11.11.2.7.1.2
Syntax Integer
Access Read and write
Description This object can be used to set the link down indication for the ports via the alarm contact:
Monitoring disabled 1
Monitoring enabled 2
The "flWorkNetPortLinkMonitoring" object can be used to set port monitoring
individually for each port.
OID 1.3.6.1.4.1.4346.11.11.11.2.7.1.3
Syntax Integer
Access Read and write
Description Indication via the alarm contact if a disabled MAC address accesses a port.
Not activated 1
Activated 2
OID 1.3.6.1.4.1.4346.11.11.11.2.7.1.4
Syntax Integer
Access Read and write
Description Indication via the alarm contact if a PoE fault has occurred.
Indication via the alarm contact not activated 1
Indication via the alarm contact activated 2
OID 1.3.6.1.4.1.4346.11.11.11.2.7.2
Syntax Integer
Access Read and write
Description This object can be used to set the indication for the configured states via the alarm
contact:
Monitoring disabled 1
Monitoring enabled 2