Technical Data and Ordering Data
6874_en_09 PHOENIX CONTACT 11-3
Test voltage 500 V AC for one minute
Maximum current consumption on US at 48 V DC 900 mA
Typical power consumption 40 W
RJ45 Interfaces – Power over Ethernet IEEE 802.3af (Continued)
Ethernet Interface (SC) – Multi-Mode
Number 2
Connection format SC duplex female connector on the switch
Wavelength 1300 nm
Laser protection Class 1 according to DIN EN 60825-1:2001-11
Minimum transmission length including 3 dB system reserve 6.4 km glass fiber with F-G 50/125 0.7 dB/km F1200
2.8 km glass fiber with F-G 50/125 1.6 dB/km F800
10 km glass fiber with F-G 62.5/125 0.7 dB/km F1000
3.0 km glass fiber with F-G 62.5/125 2.6 dB/km F1000
(Average) dynamic transmission power (fiber type) in link mode
Minimum -23.5 dBm (50/125 µm)/-20 dBm (62.5/125 µm)
Maximum -14 dBm (50/125 µm)/-14 dBm (62.5/125 µm)
Static transmission power (fiber type)
Minimum -20.5 dBm (50/125 µm)/-17 dBm (62.5/125 µm)
Maximum -11 dBm (50/125 µm)/-11 dBm (62.5/125 µm)
Minimum receiver sensitivity -31 dBm (dynamic)/-28 dBm (static)
Maximum overrange -14 dBm (dynamic)/-11 dBm (static)
Transmission speed 100 Mbps
Ethernet Interface (SC) – Single Mode
Number 2
Connection format SC duplex female connector on the switch
Wavelength 1300 nm
Laser protection Class 1 according to DIN EN 60825-1:2001-11
Minimum transmission length including 3 dB system reserve 36 km glass fiber with F-G 9/125 0.36 dB/km
32 km glass fiber with F-G 9/125 0.4 dB/km
26 km glass fiber with F-G 9/125 0.5 dB/km
(Average) dynamic transmission power (fiber type) in link mode
Minimum -15.0 dBm (9/125 µm)
Maximum -8.0 dBm (9/125 µm)
Minimum receiver sensitivity > -31 dBm (9/125 µm)
Maximum overrange > -7 dBm (9/125 µm)
Transmission speed 100 Mbps
Ethernet Interfaces – POF-SMA
Number 1 (FL IF TX/POF 100...)
2 (FL IF 2POF 100...)
Connection format F-SMA female connectors on the interface module
Data transmission rate 10/100 Mbps
Wavelength 650 nm
Minimum cable length 1 m
Transmission length including 3 dB system reserve 50 m polymer fiber with F-K 980/1000 230 dB/km